Product Comparison Guide
Compare the IoT sensors NexAscent supplies, deploys and supports in Singapore — side by side.
People Counting Sensors
Count entries and exits at doors, corridors and open spaces. Get real-time occupancy, footfall and net-flow data.
| Model | VS135 | VS125 | VS121 | VS351 | VS350 | VS360 |
|---|---|---|---|---|---|---|
| Function | ||||||
| Bi-directional counting | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Regional / zone counting | — | — | ✓ | — | — | — |
| Dwell time | — | — | ✓ | — | — | — |
| Technology | ||||||
| Sensing method | AI + 3D ToF | AI stereo vision | AI + RGB | AI + thermopile (+ radar, battery ver.) | Thermopile | IR break-beam |
| Mounting | Ceiling | Ceiling | Ceiling | Ceiling / lintel | Ceiling or wall | Wall (pair) |
| Install height | See datasheet | See datasheet | 2.3 – 4 m | 2 – 3 m | ≤ 3 m ceiling / 1.2 – 1.3 m wall | 0.7 – 1.2 m |
| Connectivity & Power | ||||||
| LoRaWAN | ✓ | — | ✓ | ✓ | ✓ | ✓ |
| Ethernet / PoE | ✓ | ✓ | ✓ | — | — | — |
| Cellular | Cellular variant | Cellular variant | — | — | — | — |
| Power | PoE or 12 V DC | PoE or 12 V DC | USB 5 V or PoE | USB Type-C or battery | Battery | Battery |
| BMS Integration | ||||||
| Direct from sensor: BACnet/IP | PoE variant | ✓ | — | — | — | — |
| Direct from sensor: MQTT / HTTP(S) API | PoE / cellular variants | ✓ | PoE variant | — | — | — |
| Via LoRaWAN gateway (BACnet/IP, Modbus TCP, MQTT) | LoRaWAN variant | — | LoRaWAN variant | ✓ | ✓ | ✓ |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
Occupancy Sensors
Detect whether desks, rooms and cubicles are in use. Ideal for workplace utilisation, meeting-room analytics and smart washroom cubicle status.
| Model | VS121 | VS321 | VS330 | VS340 / VS341 | VS370 | WS202 |
|---|---|---|---|---|---|---|
| Function | ||||||
| Use case | Workplace zones & counting | Room & desk occupancy | Toilet cubicle occupancy | Desk / seat occupancy | Room presence | Motion & light |
| Detection accuracy | Up to 98% | Up to 95% | Up to 99.5% | Up to 95% / 98% | Up to 99% | Up to 90% |
| Technology | ||||||
| Sensing method | AI + RGB | AI + PIR + RGB | PIR + ToF | PIR / PIR + thermopile | mmWave radar + PIR | PIR + light |
| Mounting | Ceiling, 2.3 – 4 m | Ceiling, 2.4 – 4 m | Ceiling 2.5 – 3 m or wall | Under desk / seat | Wall, 2.3 – 3 m | Wall or ceiling, up to 8 m |
| Connectivity & Power | ||||||
| LoRaWAN | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Ethernet / PoE | PoE variant | — | — | — | — | — |
| Power | USB 5 V or PoE | Battery | Battery (3 × Li-SOCl₂) | Battery | Battery | Battery |
| Config | Wi-Fi / web | Bluetooth | NFC | NFC | NFC + Bluetooth | NFC |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
Indoor Air Quality Sensors
Monitor comfort and air quality for healthier workplaces, Green Mark reporting and demand-controlled ventilation.
| Model | AM102 | AM103 | AM307 | AM308 | AM319 |
|---|---|---|---|---|---|
| Sensors | |||||
| Temperature & humidity | ✓ | ✓ | ✓ | ✓ | ✓ |
| CO₂ | — | ✓ | ✓ | ✓ | ✓ |
| TVOC | — | — | ✓ | ✓ | ✓ |
| Light & PIR motion | — | — | ✓ | ✓ | ✓ |
| Barometric pressure | — | — | ✓ | ✓ | ✓ |
| PM2.5 / PM10 | — | — | — | ✓ | ✓ |
| HCHO or O₃ | — | — | — | — | ✓ |
| Hardware | |||||
| E-ink display | ✓ | ✓ | ✓ | ✓ | ✓ |
| Power | Battery (7 – 9 yr) | Battery | Battery or USB | Battery or USB | USB |
| Connectivity | LoRaWAN | LoRaWAN | LoRaWAN | LoRaWAN | LoRaWAN |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
Water Leak Sensors
Catch leaks early under pantries, in plant rooms, server rooms and riser cupboards — with instant alerts before damage spreads.
| Model | WS303 | EM300-SLD | EM300-ZLD | EM300-MLD |
|---|---|---|---|---|
| Detection | ||||
| Detection type | Spot (probes) | Spot (probes) | Zone (rope) | Zone (membrane) |
| Trigger level | 0.5 mm | 5 mm | 1.5 mm | On contact |
| Cable / film | None (compact) | 1.5 m cable | 3 m cable | 400 × 400 mm film, 1 m cable |
| Hardware | ||||
| Battery life | Up to 5 yr | Up to 10 yr | Up to 10 yr | Up to 10 yr |
| IP rating | IP67 | IP67 | IP67 | IP67 |
| Connectivity | LoRaWAN | LoRaWAN | LoRaWAN | LoRaWAN |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
Temperature & Humidity Sensors
From office comfort to chillers, freezers and food storage — with continuous monitoring and alerts.
| Model | EM300-TH | EM320-TH | TS201 | TS101 | TS30X | TS60X |
|---|---|---|---|---|---|---|
| Sensing | ||||||
| Probe type | Built-in digital | Built-in digital | DS18B20 probe | DS18B20 needle | PT100 / DS18B20 / digital | PT100 / DS18B20 / digital |
| Humidity | ✓ | ✓ | TS201-TH only | — | ✓ | ✓ |
| Food-grade option | — | ✓ | — | ✓ | ✓ | ✓ |
| Hardware | ||||||
| Battery life | Up to 10 yr | ≥ 10 yr | ~3 – 9 yr | Up to 10 yr | ~5 yr (probe) | Up to 4.8 yr |
| IP rating | IP67 | IP67 | IP67 | IP67 | IP65 | IP67 |
| Operating range | -30 to 70 °C | -30 to 60 °C | -40 to 125 °C | -30 to 70 °C | -40 to 125 °C (probe) | Up to -200 to 500 °C (probe) |
| Connectivity | LoRaWAN | LoRaWAN | LoRaWAN | LoRaWAN | LoRaWAN | LoRaWAN |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
Distance & Level Sensors
Measure fill levels in washroom dispensers, bins, tanks, silos and drains. Use for smart waste collection, tank and liquid level monitoring, and flood or sewer monitoring.
| Model | WS201 | EM400-TLD | EM400-MUD | EM500-UDL | EM410-RDL |
|---|---|---|---|---|---|
| Measurement | |||||
| Technology | ToF (short range) | Time-of-flight laser | Ultrasonic | Ultrasonic | mmWave radar |
| Detection range | 1 – 55 cm | 2 – 350 cm | 3 – 450 cm | 25 – 1000 cm (probe-dependent) | 0.3 – 12 m |
| Blind zone | ~1 cm | Almost none | Small | Mid to large (probe-dependent) | Small |
| Accuracy | ±1 cm | ±2 cm | ±(1 cm + 0.3% of distance) | ±1% FS or ±(1 cm + 0.3%) | Up to ±2 mm |
| Typical use | Toilet paper & towel dispensers | Small waste bins | Medium / large waste containers | Tanks, factory liquids, flood | Sewers, tanks, liquid level |
| Hardware | |||||
| Battery life | Up to 2 yr (coin cell) | Up to 10 yr | Up to 10 yr | Up to 10 yr | ~7 yr (LoRaWAN) |
| IP rating | IP30 | IP67 | IP67 | IP67 | IP68 |
| Mounting | 3M tape | Screw to flat surface | Screw to flat surface | DIN rail, wall or pole | Bracket or tank thread |
| Operating temp. | -10 to 60 °C | -30 to 70 °C | -30 to 70 °C | Down to -30 °C, up to 65 °C | -40 to 70 °C |
| Connectivity | |||||
| LoRaWAN | ✓ | ✓ | ✓ | ✓ | ✓ |
| NB-IoT / Cat-M variant | — | ✓ | ✓ | — | ✓ |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
Current Transformers (CT)
Non-invasive energy sub-metering for distribution boards, tenants and equipment. Clamp on without cutting cables or shutting down power.
| Model | CT10X | CT30X | CTH01 |
|---|---|---|---|
| Application | |||
| Best for | Single-phase circuits & equipment | Three-phase high-current feeders | Multi-circuit DB sub-metering |
| Models / ratings | CT101 (100 A), CT103 (250 A), CT105 | CT303 (300 A), CT305 (500 A), CT310 (1000 A) | Clamps from 100 A to 4000 A (CT or Rogowski) |
| Circuits per device | 1 single-phase | 1 three-phase (3 clamps) | Up to 12 single-phase or 4 three-phase |
| Measurement | |||
| RMS current | ✓ | ✓ | ✓ |
| Accumulated current (Ah) | ✓ | ✓ | — |
| Voltage measurement | — | — | 3 voltage channels |
| Active / reactive / apparent power & kWh | — | — | ✓ |
| Power factor & THD | — | — | ✓ |
| Accuracy | ±1% (>5 A) | ±1% | ±1% (active energy) |
| Cable temperature probe | ✓ | ✓ | ✓ |
| Threshold alarms | ✓ | ✓ | ✓ |
| Hardware | |||
| Power | Self-powered from the clamp | Self-powered from the clamps | Mains powered (adapter included) |
| IP rating | IP30 | IP30 | Indoor (DB / panel) |
| Connectivity | LoRaWAN | LoRaWAN | LoRaWAN |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
IoT Controllers
Bring existing meters, PLCs, analogue sensors and dry contacts onto LoRaWAN. Read Modbus devices, count pulses, monitor 4-20 mA signals and switch relays remotely.
| Model | UC100 | UC300 |
|---|---|---|
| Application | ||
| Best for | Modbus RS485 meters and devices | Multi-signal I/O: meters, analogue sensors, relays |
| LoRaWAN class | C | C |
| Interfaces | ||
| Connection type | Terminal block | Terminal block |
| RS485 / RS232 | 1 × RS485 | 1 × RS485 + 1 × RS232 |
| Digital input | — | 4 × DI (opto-isolated, 3 – 24 VDC) |
| Pulse counting | — | ✓ |
| Relay output | — | 2 × relay |
| Analogue input | — | 2 × 4-20 mA + 2 × 0-10 V |
| PT100 | — | 2 × PT100 |
| Power & Hardware | ||
| Power | 5 – 24 VDC | 5 – 24 VDC |
| Cellular option | — | ✓ |
| IP rating | IP30 | IP30 |
| DIN rail mounting | — | ✓ (clip included) |
| Mounting options | Desktop, wall | Desktop, wall, DIN rail (35 mm) |
| Size | 70 × 45 × 13 mm | 93 × 70 × 22 mm |
| Features | ||
| IF-THEN local rules | ✓ | ✓ |
| Data storage & retransmission | — | ✓ |
| Milesight D2D | ✓ | ✓ |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
LoRaWAN Gateways
Connect your LoRaWAN sensors to the network. Choose by environment: compact indoor units for blind spots, industrial indoor units for buildings, IP-rated units for semi-outdoor and rooftop sites, and a building IoT gateway for BMS integration.
| Model | UG63 Mini | UG56 Industrial | UG65 Indoor | UG67 Outdoor | EG71 Building |
|---|---|---|---|---|---|
| Application | |||||
| Best for | Indoor blind-spot filling, small sites | Indoor industrial | Indoor & semi-outdoor buildings | Outdoor / rooftop | BMS integration, new builds & retrofits |
| Relative range | ★★★ | ★★★★ | ★★★★ | ★★★★★ | Indoor building |
| Channels | 8 (half-duplex) | 8 (half-duplex) | 8 (half / full-duplex) | 8 (half / full-duplex) | 8 (half-duplex) |
| Antenna | 1 × external | 1 × external | Internal or external | 2 × external | 1 × external (SMB) |
| Backhaul | |||||
| Ethernet | 10/100 Mbps | 10/100 Mbps | 10/100/1000 Mbps | 10/100/1000 Mbps | 2 × 10/100/1000 Mbps |
| Wi-Fi | Config only | ✓ | ✓ | ✓ | ✓ |
| Cellular (4G) | ✓ (built-in) | Optional | Optional | Optional | Optional |
| PoE | Via splitter | ✓ | ✓ | ✓ | ✓ |
| GPS | — | — | — | ✓ | — |
| Hardware | |||||
| Power supply | USB Type-C, 5 – 12 VDC | PoE, USB Type-C | PoE, 9 – 24 VDC | PoE, 12 VDC (M12) | PoE, 24 V AC/DC, USB Type-C |
| IP rating | IP30 | IP30 | IP65 | IP67 | IP30 |
| Mounting | Desktop, wall, ceiling | Desktop, wall, ceiling | Desktop, wall, pole | Wall, pole | See datasheet |
| Operating temp. | -20 to 50 °C | -20 to 60 °C | -40 to 70 °C | -40 to 70 °C | See datasheet |
| Software | |||||
| Embedded network server | Cloud-based NS | ✓ | ✓ | ✓ | ✓ |
| Listen Before Talk (LBT) | — | ✓ | — | ✓ | ✓ |
| Python SDK / Node-RED | — | ✓ | ✓ | ✓ | Yes, plus Docker |
| BMS protocols (BACnet / Modbus / KNX) | — | — | — | — | ✓ |
| On-board I/O | — | — | — | — | 8 UI, 4 DI, 3 relay, 4 AO, 2 RS485, M-Bus |
✓ Supported · — Not applicable · Battery life and range are indicative and depend on configuration, installation and environment. Cellular is available on selected model variants.
Not sure which sensor fits your site?
Tell us about your building and use case. We will recommend the right hardware, gateway and dashboard — and handle deployment, installation and ongoing maintenance.
Milesight model names are used to identify products supplied by NexAscent as an authorised reseller. Specifications are summarised from manufacturer datasheets and may change; please refer to the latest datasheet or contact us for project-specific advice.